LogoLogo
AboutSupport
3.0
3.0
  • Unifi Documentation
  • Release
    • Unifi 3.0 Release Notes
      • Unifi 2.2 Release Notes
      • Unifi 2.1 Release Notes
      • Unifi 2.0 Release Notes
    • Hotfixes
    • Setup
  • Overview
    • Quick Tour
    • Supported Features
    • Application Modules
    • Data Model
  • Integration Guides
    • Outbound Incident Guide
      • Getting Started
      • Process
      • Integration
      • Connection
      • Create Scenario
        • CreateIncidentResponse Message
        • CreateIncidentResponse Fields
        • CreateIncident Message
        • CreateIncident Fields
        • Trigger
        • Test CreateIncident
      • Update Scenario
        • Response Message
        • UpdateIncident Message
        • UpdateIncident Fields
        • Test UpdateIncident
      • Resolve Scenario
        • ResolveIncident Message
        • ResolveIncident Fields
        • Test ResolveIncident
      • Build - Integration Level
      • Conclusion
    • Bidirectional Asynchronous Incident Guide
      • Getting Started
      • Process
      • Web Service
      • Integration
      • Connection
      • Create Scenario
        • Response Message
        • CreateIncidentReceipt Message
        • CreateIncidentReceipt Fields
        • CreateIncident Message
        • CreateIncident Fields
        • Trigger
        • Test CreateIncident
      • Update Scenario
        • Receipt Message
        • UpdateIncident Message
        • UpdateIncident Fields
        • Test UpdateIncident
      • Resolve Scenario
        • ResolveIncident Message
        • ResolveIncident Fields
        • Test ResolveIncident
      • Build - Integration Level
      • Build the Other Half
        • Move the Integration
        • Reconfigure the Connections
      • Conclusion
    • Incident Update Poller Guide
      • Polling
        • Poll Processor
        • Poller
      • Inbound Message
        • UpdateIncidentInbound Message
        • UpdateIncidentInbound Fields
      • Message Identification
      • Bond Identification
        • Edit Incident Form
        • Edit CreateIncident Message
      • Test Update Poll
      • Conclusion
    • Incident Multiple Message Poller Guide
      • Polling
        • Poll Processor
        • Poller
      • Inbound Messages
        • ResolveIncidentInbound Message
        • ResolveIncidentInbound Fields
      • Testing
        • Test UpdateIncidentInbound
        • Test ResolveIncidentInbound
      • Conclusion
    • Incident Create Poller Guide
      • Polling
        • Connection Variables
        • Poll Processor
        • Poller
      • Messages
        • CreateIncidentInboundReceipt Message
        • CreateIncidentInboundReceipt Fields
        • CreateIncidentInbound Message
        • CreateIncidentInbound Fields
      • Build - Integration Level
      • Test Create Poll
      • Conclusion
    • Incident Parent and Child Poller Guide
      • Polling
        • Connection Variables
        • Child Poll Processor
        • Child Poller
        • Parent Poll Processor
        • Parent Poller
      • Inbound Messages
      • Testing
        • Test UpdateIncidentInbound
        • Test ResolveIncidentInbound
      • Conclusion
    • Incident Attachment Poller Guide
      • Polling
        • Connection Variables
        • Edit Endpoint URLs
        • Get Attachment Poll Processor
        • Get Attachment Poller
        • Select Attachments Poll Processor
        • Select Attachments Poller
        • Edit Child Poll Processor
        • Edit Child Update Poller
      • Messages
        • AddAttachmentInbound Message
      • Testing
        • Test Outbound Scenarios
        • Test CreateIncidentInbound
        • Test UpdateIncidentInbound
        • Test ResolveIncidentInbound
        • Test AddAttachmentInbound
      • Conclusion
  • Feature Guides
    • Packager Feature Guide
      • Instructions
    • Error Handling Tools Feature Guide
      • Retry
      • Replay
      • Ignore
      • Repair
      • Pause and Resume
    • Unifi Test Assistant Feature Guide
      • Generating Tests
      • Running Tests
      • Exploring Results
  • Bonding
    • Bonds
    • Bonded Attachments
  • Transport
    • Transport Data Flow
    • Snapshots
    • Transactions
    • Stages
    • HTTP Requests
  • Configuration
    • Processes
    • Integrations
    • Connections
    • Messages
    • Message Scripts
    • Fields
    • Field Maps
    • Response Actions
    • Event Actions
  • Polling
    • Pollers
    • Poll Processors
    • Poll Requests
    • Large Response Payloads
  • Testing
    • Integration Tests
    • Test Scenarios
    • Test Scenario Data
    • Test Results
    • Test Scenario Results
  • Administration
    • Activity Logs
    • Data Stores
    • Properties
    • Scheduled Scripts
    • System Logs
    • Self-test
  • Scripting
    • Variables
    • Snippets
  • Attachments
    • Attachment Handling
    • Multipart Form Data
Powered by GitBook
On this page
  • Field: incident.number
  • Build
  • Message Scripts

Was this helpful?

Export as PDF
  1. Integration Guides
  2. Incident Create Poller Guide
  3. Messages

CreateIncidentInboundReceipt Fields

We will utilise the Field & Field Map records to configure the Message Scripts for the CreateIncidentInboundReceipt Message.

PreviousCreateIncidentInboundReceipt MessageNextCreateIncidentInbound Message

Last updated 3 years ago

Was this helpful?

Field: incident.number

The ‘incident.number’ (Integration level) Field record should already be in place (i.e. with Active set to false). This was automatically created by Unifi when we first created the Message level record when completing the Incident Update Poller Guide. We will now create its Message level counterpart.

From the CreateIncidentInboundReceipt Message, navigate to Message > Fields.

Your CreateIncidentInboundReceipt Fields page should look like this:

1) Find the incident.number (Integration level) Field & set Active to true.

The ‘Build Integration’ button becomes visible in the banner and the empty circle icon next to the Field name turns green & contains a green ‘check’ (to indicate that Message level configuration exists for this Field) when we set Active to true. (Note: the empty 'circle icon' indicates that the Integration level Field is available to add to the Message.).

By setting the Active flag to true on the Integration level Field record listed on the Message, Unifi has automatically created the Message level counterpart.

Build

We don't need to configure any more the Field records for the CreateIncidentInboundReceipt Message, so we are ready to build our message scripts.

2) Click on Build Message.

You will see the 'Message build successful' Info Message.

3) Navigate to Advanced > Script Editor > View > Outbound to view the auto-generated code.

Your Script Editor fields should look like this:

Message Scripts

We will look at the Message Scripts in turn.

Source to Stage:

Your Source to Stage Message Script should look like this:

//===== [ws] Begin Unifi Auto Generated Code =====//

/*
 * This code (between the Begin and End comments) is generated from the
 * Field and Field mapping records which are configured as part of the integration.
 *
 * All code either above or below the comments will be automatically maintained
 * through the build cycle.
 *
 * WARNING: Do not edit the Begin or End comments.
 */

x_snd_eb.ws_console.checkpoint("MessageScript")

x_snd_eb.ws_console.execute("Mapping incident.number [x_snd_eb_field.do?sys_id=d4dba3aadb7dbc501831aab35b961994]", function () {
  log.debug("Field map: PI - String [x_snd_eb_field_map.do?sys_id=da997f7a1b51b81090dfdb9ebd4bcb5e]");
  
  var default_value = (function () {
    return '';
  })();
  
  // Determines whether this instance of the field map is for a mandatory field
  var is_mandatory = false;
  
  if (is_mandatory) {
    $stage.number = '' + (source.number || default_value);
  } else if (source.number != '') {
    $stage.number = '' + source.number;
  }

});

var error = x_snd_eb.ws_console.findCheckpointError("MessageScript");
if (error) throw error.message;

//===== [ws] End Unifi Auto Generated Code =====//

Stage to Request:

Your Stage to Request Message Script should look like this:

//===== [ws] Begin Unifi Auto Generated Code =====//

/*
 * This code (between the Begin and End comments) is generated from the
 * Field and Field mapping records which are configured as part of the integration.
 *
 * All code either above or below the comments will be automatically maintained
 * through the build cycle.
 *
 * WARNING: Do not edit the Begin or End comments.
 */

x_snd_eb.ws_console.checkpoint("MessageScript")

x_snd_eb.ws_console.execute("Mapping incident.number [x_snd_eb_field.do?sys_id=d4dba3aadb7dbc501831aab35b961994]", function () {
  log.debug("Field map: PI - String [x_snd_eb_field_map.do?sys_id=da997f7a1b51b81090dfdb9ebd4bcb5e]");
  payload = payload || {};
  var $payload = payload;
  
  // Determines whether this instance of the field map is for a mandatory field
  var is_mandatory = false;
  
  if (is_mandatory) {
    $payload.correlation_id = '' + $stage.number;
  } else if ($stage.number) {
    $payload.correlation_id = '' + $stage.number;
  }

});

var error = x_snd_eb.ws_console.findCheckpointError("MessageScript");
if (error) throw error.message;

//===== [ws] End Unifi Auto Generated Code =====//

Next, we'll configure the CreateIncidentInbound Message.